The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 apply to tenancies where the occupier lives in the property as their only or main residence. A typical Airbnb guest has a home somewhere else, so an ordinary short stay is not covered and the 5-yearly EICR duty does not apply automatically. It can apply if the short let is in fact someone's home, for example a rolling monthly booking by a worker with no other address.
A short let is still covered by the Regulatory Reform (Fire Safety) Order 2005. The government's guide for small paying guest accommodation says the electrical installation should be inspected and tested at least every five years, and an EICR is the usual way to show that has been done. Some holiday-let insurers ask for a current EICR as well, so check your policy wording.
We carry out short-let EICRs from £89.99 with same-day NICEIC certification, and bundle a BS 5839-6 Grade D smoke alarm interconnection test in the same visit. Slots scheduled around guest turnover so the next booking is unaffected.
Why Electrician London
90-day rule, explained on the call
London's 90-night limit comes from section 25A of the Greater London Council (General Powers) Act 1973. It decides whether you need planning permission, not which safety rules apply. We explain how it fits with the EICR before we attend.
Insurer-ready certificate
Some holiday-let insurers ask for a current EICR at inception or renewal. Our NICEIC certificate records the result and every C1, C2, C3 or FI code in the standard format, ready to send to your insurer.
BS 5839-6 smoke check included
For paying guest accommodation the gov.uk fire guide recommends interlinked, mains-powered smoke and heat alarms with battery backup (Grade D1). We test smoke alarm interlinking and check CO alarms in the same visit at no extra cost.
Same-day for the next booking
Test slot booked around guest turnover. Same-day digital certificate emailed before the next check-in.
Airbnb / short let EICR pricing
Standard residential pricing. Smoke + CO alarm interconnect test included at no extra charge.
Studio or 1-bed short let
£89.99
2–3 bedroom short let
£99.99
4–5 bedroom short let
£110.99
Smoke + CO alarm interconnect test
Smoke alarm interlink check + CO presence test
Included
Bundle with EPC
EPC and EICR in one visit
Save 10%
What's covered in a short-let EICR
- Full BS 7671:2018 + A4:2026 inspection
- BS 5839-6 Grade D smoke alarm interconnection test
- CO alarm presence and operation check
- Type A RCD compliance verification
- Insurer-formatted NICEIC certificate
- Earth bonding (kitchen, bathroom, services)
- Consumer unit and circuit-by-circuit testing
- Clear C1/C2/C3/FI coding
- Same-day digital certificate
- Slot scheduled around guest turnover
Frequently asked questions
If I'm inside the 90-night cap, do I still need an EICR?
In most cases the law does not require one, inside the cap or outside it. The 2020 Regulations cover tenancies where the occupier lives there as their only or main residence, and a typical holiday guest does not. The 90-night cap is a separate planning rule. We still recommend an EICR: the gov.uk fire guide for paying guest accommodation says the installation should be inspected and tested at least every five years, and the EICR is the normal evidence. If the let is in fact someone's main home, the 2020 Regulations apply in full.
Do short-let insurers require a current EICR?
Some do and some do not. A number of holiday-let policies ask for a current EICR or set electrical safety conditions, so read your own policy wording. Separately, if your insurer does not know the property is let to short-stay guests, a claim can be refused whatever state the wiring is in.
What if my short let is in a multi-tenant building or shared house?
It depends on the arrangement. If the property is a licensed HMO, the licence conditions in Schedule 4 to the Housing Act 2004 require every electrical installation to be in proper working order and safe, and the appliances you supply to be safe. If you live there and let a room to someone who shares your kitchen, bathroom or living room, the 2020 Regulations do not apply to that let. See our HMO EICR page for the HMO scope and pricing.
How does the EICR overlap with short-let fire safety?
The EICR covers the fixed electrical installation. Fire safety in a short let comes under the Fire Safety Order: you need a recorded fire risk assessment, and the gov.uk guide recommends interlinked mains smoke and heat alarms with battery backup in areas where a fire might start, plus carbon monoxide detectors where there is a gas or solid fuel appliance. We test smoke alarm interlinking and check CO alarms at the same visit as the EICR.
Do Booking.com, Vrbo or Airbnb require an EPC?
Platform rules change, so check the host terms of each site you list on. If you need an EPC as well, we can carry it out on the same visit as the EICR with a 10% bundle discount.
What about gas safety on a short let?
Yes, the gas rules apply. Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 covers premises occupied for residential purposes, for money, under a lease or a licence, and that includes paying guests. Each gas appliance and flue must be safety checked at least every 12 months and a record kept. For stays of 28 days or less, the latest record can be displayed prominently in the property instead of handed over. We hold Gas Safe registration and run the CP12 alongside the EICR if needed. See the CP12 page.