Grade D under BS 5839-6:2019 means an alarm powered from the mains supply with an integral standby battery capable of running the alarm for at least 72 hours. The mains feed is taken from the lighting circuit (not a socket — so the alarm is always live when the main switch is on) and the battery is sealed for the full ten-year life of the head. There is no battery to change and no annual chirp at 3am.
The Smoke and Carbon Monoxide Alarm (England) Regulations 2015, as amended in October 2022, require a working smoke alarm on every storey of a rented home but do not say how it is powered. Grade D becomes a requirement through HMO licence conditions, which in London usually follow the LACORS fire safety guidance, and through Building Regulations for new builds, conversions and loft conversions. Grade F, battery only, still meets the Regulations in a single-household let but is rarely accepted in a licensed HMO.
Electrician London installs Grade D systems at £180 per point covering the alarm, the wiring, the interconnect and the BS 5839-6 commissioning certificate. Aico, FireAngel and Kidde heads are all available — the survey identifies the right schedule and the right head for each room.
Why Electrician London
Mains-powered with battery backup
Lighting-circuit feed plus a sealed 72-hour lithium standby. Survives the power cuts that take out battery-only alarms first.
BS 5839-6:2019 compliant
Designed, installed and commissioned to the current standard. Certificate handed over on the day for licensing renewals.
Required in HMOs and new builds
Most London HMO licence conditions and Building Regulations Part B call for mains alarms with battery backup. We fit it as standard in rentals.
Ten-year sealed battery
No annual battery change, no 3am chirp. End-of-life means head replacement, which we do like-for-like at £180 per point.
Grade D smoke alarm pricing
Per-point pricing covers alarm, wiring, interconnect and certificate.
Grade D smoke alarm install
Mains + battery, BS 5839-6
£180 / point
Grade D heat alarm (kitchen)
Mandatory in kitchens under LD2
£170 / point
Grade D interlinked system (3-4 alarms)
Typical 1-2 bed HMO or family home
£550
Grade D HMO upgrade (5-7 alarms)
Full LD2 schedule, multi-storey HMO
£750-£1,400
Annual BS 5839-6 inspection
Engineer test, logbook entry
£85
What's included in a Grade D install
- Mains supply taken from the lighting circuit
- 72-hour sealed-battery backup
- BS 5839-6:2019 compliant alarm head
- Wired or radio-linked interconnect
- LD2 schedule designed to the property
- Commissioning test under load
- BS 5839-6 certificate and logbook
- Minor Works Electrical Installation Certificate
Frequently asked questions
What does Grade D actually mean?
Grade D is BS 5839-6 shorthand for "mains-powered with an integral standby battery capable of at least 72 hours of standby plus four minutes of alarm". In practice it is what London licensing boroughs expect in HMOs and what Building Regulations expect in new homes: mains feed plus sealed lithium backup.
Is Grade D mandatory in rentals?
Not in every rental. The October 2022 amendment to the 2015 Regulations extended the alarm duty to social landlords and added a duty to repair faulty alarms, but the Regulations still do not specify mains or battery power. Grade D is mandatory where an HMO licence or Building Regulations require it, and it is our default on rental installs.
What is the 72-hour battery rule?
The standby battery must be able to maintain the alarm in quiescent (listening) mode for at least 72 hours after mains failure, then sound for at least four minutes if smoke is detected. Modern sealed-lithium alarms exceed this by a factor of three.
Where is Grade D allowed and where is it required?
Required in most licensed HMOs through licence conditions. Required in new-build domestic property under Building Regulations Part B. Allowed everywhere as a voluntary upgrade. The only setting where Grade F (battery only) remains practical is owner-occupied homes — and even then, mains-powered Grade D is the safer choice.
Can I get Grade D radio-linked?
Yes. Aico Ei3000-series, FireAngel Pro and Kidde Multipro all offer radio-link modules that snap into a Grade D base. The base still wires to mains, the radio module just handles the interlink signal. Identical compliance to hard-wired.
How long do Grade D alarms last?
Ten years from the date stamped on the head. After ten years the head chirps end-of-life and must be replaced. We replace like-for-like at £180 per point on existing wiring.
Why feed from the lighting circuit?
BS 5839-6 requires the mains feed to come from a circuit that is on whenever the main switch is closed. The lighting circuit is the standard choice because it is always live when the consumer unit is on and any tripping is immediately obvious to occupants. Sockets are not allowed because they can be unplugged.
Can I upgrade an existing Grade F installation to Grade D?
Yes. We remove the battery-only heads, run a feed from the lighting circuit to each location, fit Grade D bases and commission the new system. Typical 3-bed conversion costs £550-£750 depending on cable routing. The replacement is a Minor Works job under BS 7671.